Installation instructions for µPREMIUM-MFS
If the mounting plate is used, the reader cable may be brought out of one of four exit points on the mounting plate: top, bottom, left or right. This enables the cable to be run on the surface of the wall. If no mounting plate is used, a minimum hole size of 6,5 mm must be drilled in the wall at the cable exit position as shown above to allow the cable to exit perpendicular to the reader. The
optional mounting plate may also be used when mounting the reader on a metal
surface to reduce the negative effects of metal on the read range. Connections
Note
1. Baud rate is configurable Note
2. Open collector has a 10k internal pullup to 5V Configuration Normal
Operation Once
configured, the reader will read a single block of data stored on a Mifare card
and output this data in a chosen format. The
choice of which sector and block to read, which authentication KEY to use, and
which output format to use, is decided by the user.
Using the µMFPROG Mifare card programmer, a configuration card may be made
using the parameters the user has chosen. This
card must be presented to the µPREMIUM-MFS reader when it is in the factory reset
state. Presenting this card to the
reader will load these settings into the reader and the reader is now
configured. The
Configuration Card may be used on as many readers as required.
Following is a full list of configurable reader options :
Factory
Reset State A
new reader will start in the factory reset state and has the following
functionality: LEDS The
red and green LEDS will flash alternatively ON and OFF with a period of 1
second. The LEDS will not respond to any card reading. Card
in Field The
reader will poll a Mifare card in the field for its UID and if received will
attempt to read ‘Configuration’ data. If
the card contains valid configuration data, the card's configuration settings
will be loaded into the reader which will reset and resume operation in a
configured state. Note
that all LEDs will be off in the configured state. Beeper The
beeper will respond with a single 500ms beep if a valid configuration card was
read and the settings were accepted. Configuration
Card Configuration
cards can be programmed using the µMFPROG Mifare card programmer.
A Mifare Std 1k card is used as a configuration card.
The reader uses a factory defined KEY to read the configuration card.
To prevent unauthorised re-configuring of readers in the future, the user
can do one of two things : 1.
Disallow future re-configuration of the reade 2.
Choose a new key to be used for re-configuring the reader If
you disallow future re-configuration, the reader configuration can only be set
back to the factory reset state by reloading the reader firmware. |
|
Contact Information
Send e- mail to info@micronid.com with