Installation instructions for OEM
modules
125 kHz Module
Dimensions
Connections
|
Nr.
|
Pin
|
Function
|
|
Description
|
|
1
|
+UB
|
Power
Supply
|
|
|
|
2
|
GND
|
Ground
for Power Supply and Data
|
|
GND
|
|
3
|
Analog
IN
|
Analog
input
|
|
Do
not connect
|
|
4
|
/Reset
|
Reset
|
|
Reader
Reset when connected to GND
|
|
5
|
SCL
(Hitag only)
|
Digital
In-/Output
|
|
Do
not connect
|
|
6
|
SDA
(Hitag
only)
|
Digital
In-/Output
|
|
Do
not connect
|
|
7
|
RXD/
B-
(Hitag
only)
|
RS232
or RS485
|
|
RXD
on TTL level or
optional
on buffered RS 232 level
Do
not connect for Wiegand or Clock&Data versions
|
|
8
|
TXD/
A+
(Hitag
only)
|
RS232
or RS485
|
|
TXD
on TTL level or
optional
on buffered RS 232 level
Do
not connect for Wiegand or Clock&Data versions
|
|
9
|
I/O
1
|
Clock
Data0 RX
|
|
Data
output line
|
|
10
|
I/O
2
|
Data
Data1 TX
|
|
Data
output line
|
|
11
|
I/O
3
|
Digital
In-/Output
|
|
Do
not connect
|
|
12
|
I/O
4
|
Digital
In-/Output
|
|
Do
not connect
|
|
13
|
I/O
5
|
Digital
In-/Output
|
|
Do
not connect
|
|
14
|
I/O
6
|
Card
Load
|
|
Ca.
0,5 s active low when tag detected
(not
active for RS232 or TTL versions)
|
Attention:
Power supply must be well regulated, stable and free of noise.
13,56 MHz Module
Dimensions
module dimensions
external antenna dimensions
Connections
|
Nr.
|
Pin
|
Function
|
|
Description
|
|
1
|
+UB
|
Power
Supply
|
|
|
|
2
|
GND
|
Ground
for Power Supply and Data
|
|
GND
|
|
3
|
Analog
In
|
Analog
Input
|
|
Do
not connect
|
|
4
|
/Reset
|
Reset
|
|
Reader
Reset when connected to GND
|
|
5
|
SCL
|
Digital
In-/Output
|
|
Do
not connect
|
|
6
|
SDA
|
Digital
In-/Output
|
|
Do
not connect
|
|
7
|
RXD/
B-
|
RS232
or RS485
|
|
RXD
on TTL level or
optional
on buffered RS 232 level
Do
not connect for Wiegand or Clock&Data versions
|
|
8
|
TXD/
A+
|
RS232
or RS485
|
|
TXD
on TTL level or
optional
on buffered RS 232 level
Do
not connect for Wiegand or Clock&Data versions
|
|
9
|
I/O
1
|
Digital
Output
|
|
Clock
or Data 0
|
|
10
|
I/O
2
|
Digital
Output
|
|
Data
or Data 1
|
|
11
|
I/O
3
|
Digital
In-/Output
|
|
Do
not connect
|
|
12
|
I/O
4
|
Digital
In-/Output
|
|
Do
not connect
|
|
13
|
I/O
5
|
Digital
In-/Output
|
|
Do
not connect
|
|
14
|
I/O
6
|
Digital
Output
|
|
Ca.
0,5 s active low when tag detected
(not
active for RS232 or TTL versions)
|
|
15
|
ANT1
|
Connection
for external antenna
|
|
Connect
to ANT1 of external antenna
(for Mifare & Legic )
|
|
16
|
ANT2
|
Connection
for external antenna
|
|
Connect
to ANT2 of external antenna
(for Mifare & Legic )
|
|
17
|
ANT3
|
Connection
for external antenna
|
|
Connect
to ANT3 of external antenna
(for Mifare only )
|
|
18
|
ANT4
|
Connection
for external antenna
|
|
Connect
to ANT4 of external antenna
(for Mifare only )
|
Attention:
Power supply must be well regulated, stable and free of noise.
Note
:
1)
For Legic modules, only antenna pins ANT1 & ANT2 need to be connected.
Mifare modules have all 4 ANT pins connected.
2)
After power-up, all inputs are 'OFF', thus on +5V over a pull-up resitors; and
the outputs are not active, thus on +5V.
3)
Clock&Data versions of the µOEM module output the decimal converted card
number.
|